Home › Sizing calculator
Backup power sizing calculator
List what you want to keep running during an outage. The calculator adds up the watts and watt-hours and suggests a battery size, inverter size and generator size. It runs in your browser; nothing is sent anywhere.
| Appliance | Qty | Running W | Extra starting W | Hours/day | Wh/day |
|---|
Results
0 Wtotal running watts (everything on at once)
0 Wpeak watts when the biggest motor starts
0 Whenergy used per day
0 Whbattery capacity needed (days x daily use, with 15% inverter loss)
0 Winverter / power station output (running x 1.25)
0 Wgenerator size (covers starting surge)
How the math works
- Watt-hours per day = quantity × running watts × hours per day. A 150 W fridge compressor that runs about 8 hours a day uses about 1,200 Wh.
- Battery size = daily Wh × days ÷ 0.85, to allow for inverter losses. Usable capacity varies by product, so check the specs.
- Inverter size = total running watts × 1.25 for headroom, rounded up to a common size. Its surge rating must also cover the "extra starting watts" of motors like fridges and pumps.
- Generator size = the larger of running watts × 1.25 or running watts plus the single biggest starting surge.
Appliance watts in the list are typical starting points, not measurements. Your appliance's label or a plug-in watt meter gives the real number. A fridge's hours are the time its compressor actually runs, not 24. Anything wired in (well pumps, furnaces, central AC) needs a transfer switch or inlet installed by a licensed electrician. The method follows the U.S. Department of Energy's guide to estimating appliance energy use.